The table below may help with the choice of which product family best fits
your process or application.
There are also drawbacks to each of the adhesive families to be aware
of. One-part moisture RTV cures can be slow, especially at higher bond
line thicknesses or when confined. Two-part room temperature condensation
cures have limited working life, once mixed. Heat curing products can
sometimes have their cure inhibited by other materials in the electronic part